R290 refrigerant is commercial-grade propane (C3H8), a natural hydrocarbon with zero ozone depletion potential and a global warming potential of about 3. It is now one of the most widely used low-GWP options in small commercial refrigeration, split air conditioners and heat pumps. The trade-off is flammability: R290 is classed A3 by ASHRAE and ISO, so it must be handled under strict rules and used only in equipment designed for it. This guide explains R290 properties, how it compares with R22, R32 and R410A, the safety rules that matter for storage, transport and service, and where it is typically applied. It is written for importers, distributors and HVAC and refrigeration businesses buying worldwide.

Key takeaways

  • R290 is propane with ODP 0 and a GWP of roughly 3, which is why regulators in many regions favour it as HFCs are phased down.
  • It is highly flammable (safety class A3), so equipment charge size, ventilation and ignition-source control are central to R290 safety.
  • R290 is not a drop-in replacement for R22, R410A or R32. Retrofitting existing equipment designed for non-flammable refrigerants is generally not permitted.
  • Charge limits depend on the standard, equipment type and room size, and they differ between countries. Always check the edition adopted locally.
  • For trade buyers, purity, correct valve connections, packaging type and compliance documents matter as much as the gas itself.

What Is R290 Refrigerant?

Chemical identity and naming

R290 is the ASHRAE designation for propane, CAS number 74-98-6. In refrigeration it is a single-component fluid, so it has no temperature glide and does not fractionate when it leaks. That makes it simpler to charge and service than many blends.

An important distinction: refrigerant-grade R290 is not the same product as LPG or cooking-gas propane. LPG normally contains an odorant, other hydrocarbons and higher moisture, all of which can harm a sealed refrigeration circuit. Refrigerant-grade propane is purified, dried and normally supplied without strong odorant. That also means a leak is hard to smell, which has direct safety consequences covered below.

Why R290 is back in focus

Propane was used in early refrigeration more than a century ago, then displaced by CFCs, HCFCs and HFCs. Two policy drivers brought it back. The Montreal Protocol phased out ozone-depleting substances such as R22, and the Kigali Amendment sets a schedule to reduce HFC consumption worldwide. The timetable varies by country group, and regional rules such as the EU F-gas regulation can be stricter. As HFC quotas tighten, manufacturers are moving small, factory-sealed systems to R290 and R600a. Our R290 and R600a natural refrigerants wholesale supply guide covers the market side of that shift.

R290 Properties at a Glance

Thermodynamic behaviour

The table gives typical R290 properties. Figures are rounded and should be confirmed against the supplier safety data sheet.

PropertyR290 (propane)
Chemical formulaC3H8
Normal boiling pointabout -42 °C (-44 °F)
Critical temperatureabout 97 °C (207 °F)
Vapour pressure at 25 °C (77 °F)about 9.5 bar absolute (approx. 138 psia)
ODP / GWP (100-year)0 / about 3
Safety classA3 (lower toxicity, higher flammability)
Lower flammable limitabout 2.1 % by volume in air
Upper flammable limitabout 9.5 % by volume in air
Auto-ignition temperatureabout 450–470 °C (840–880 °F)

Its pressures are close to R22 and noticeably lower than R410A, so components and compressors designed for R290 can be relatively conventional in pressure rating. Liquid density is low, so the mass of refrigerant needed for the same system is much smaller than with R22 or R410A. A typical system charge is often a fraction of the equivalent HFC charge by mass, although the exact ratio depends on design. Latent heat is high, which supports good energy efficiency, particularly with compact heat exchangers.

Oil and materials compatibility

Propane is compatible with mineral oil, POE and PAG-type lubricants, but the oil must be the one specified by the compressor maker, because propane dissolves in oil and alters viscosity. Use compressors approved for R290. Their electrical parts (relays, overloads, terminals) are designed so that arcing cannot ignite escaping gas. Copper and aluminium are normal materials, and standard elastomers should be checked for compatibility with hydrocarbons.

R290 Flammability and Safety Classification

What the A3 class means

In ISO 817 and ASHRAE 34, the letter shows toxicity (A is lower toxicity) and the number shows flammability (3 is highest). So R290 is not toxic at normal exposure levels, but it can burn or explode when mixed with air in the right range and ignited. Is R290 flammable? Yes, clearly. It is also an asphyxiant in very high concentrations because it displaces oxygen.

Flammability limits in practice

Propane burns only between roughly 2.1 % and 9.5 % by volume in air. Below the lower limit the mixture is too lean, above the upper limit too rich. In a leak, gas is heavier than air (about 1.5 times), so it sinks and pools at floor level, along drains, in pits and under cabinets. A small leak in a large, ventilated room usually dilutes below the lower limit, while the same leak in a small closed space may not. Ignition sources include sparks from switches, thermostats, static discharge, hot surfaces, open flames and non-rated tools.

Why charge size is the main safety lever

The most effective safety measure is limiting how much refrigerant can escape. Standards therefore tie the permitted charge to the equipment type and, in some cases, to the floor area and installation height. This is why R290 appears first in small sealed equipment and is only now moving into larger split systems with design-specific safeguards.

R290 Safety Rules for Handling, Storage and Service

These points are general good practice, not a substitute for local law, the supplier safety data sheet or equipment manufacturer instructions. Rules for flammable gases differ between countries, so check which regulations apply in your market.

Cylinder storage and transport

  • Store cylinders upright, secured and protected from heat above the temperature stated on the label, typically not above 50 °C (122 °F).
  • Keep them in a ventilated area away from ignition sources, oxidising gases, drains and basements.
  • Transport as a flammable gas (UN 1978 propane) with correct labelling, valve protection and documents under ADR, IMDG, IATA or DOT rules as applicable to your route.
  • Never fill a cylinder beyond its permitted fill ratio. Use only cylinders and valves designed for flammable gases. Valve outlet threads differ by region, and left-hand threads are common for fuel gases, so confirm compatibility before connecting hoses.

Rules for technicians

  1. Be trained and, where required, certified for flammable refrigerants. Requirements differ by country.
  2. Remove ignition sources and check the work area with a hydrocarbon-capable gas detector. Halogen leak detectors do not detect propane reliably.
  3. Use recovery machines, vacuum pumps and scales rated for flammable refrigerants, and ventilate the area.
  4. Purge and flush the circuit with oxygen-free nitrogen before any brazing or cutting.
  5. Charge by weight, never above the amount on the nameplate, and keep a fire extinguisher at hand.
  6. Do not vent refrigerant to the atmosphere unless local regulations explicitly allow it. Recover it into approved cylinders.

Leak detection and ventilation

Because refrigerant-grade R290 has little odour, rely on detectors and good ventilation, not on smell. In commercial installations, fixed sensors, forced ventilation and alarms are common design features. After a suspected leak, ventilate first, switch off ignition sources from outside the area where possible, and do not operate electrical switches inside the gas cloud.

R290 Charge Limits and Equipment Standards

How standards limit charge

The IEC 60335 family is the main international reference. Part 2-24 covers household refrigerators and freezers, Part 2-89 covers commercial refrigeration equipment, and Part 2-40 covers air conditioners and heat pumps. Older editions limited hydrocarbon charges to about 150 g per circuit for many sealed appliances, while later editions allow higher charges in specific commercial categories and calculate allowable charge for air conditioners from room area and installation height. EN, UL and national standards align with these in different ways and on different timetables. Because of this, a charge that is legal in one market may not be accepted in another, so exporters should confirm the current edition adopted at the destination.

Design features that make small charges safe

  • Sealed, brazed circuits with fewer joints and no field-made flare connections where possible.
  • Ignition-safe electrical components, or relays and controls placed outside the refrigerant path.
  • Micro-channel or small-diameter heat exchangers that reduce internal volume.
  • Separate secondary loops in larger systems so the propane stays in a compact, outdoor or ventilated unit.
  • Warning labels and, where required, leak sensors that start fans or shut down the unit.

R290 vs R22, R32 and R410A

R290 vs R22

R22 is an HCFC being phased out under the Montreal Protocol, with GWP around 1,810. R290 has similar operating pressures, so it can match R22 capacity in a purpose-built system with a smaller charge. However, R290 is not a drop-in for R22. Existing R22 equipment was not designed for flammable gas, and retrofitting it with propane is prohibited or strongly discouraged in most standards and jurisdictions. Servicing R22 equipment remains a separate market, covered in our R22 Freon gas 13.6 kg export guide.

R290 vs R32 and R410A

R32 (A2L, mildly flammable, GWP about 675) and R410A (A1, non-flammable, GWP about 2,088) work at higher pressures than R290. R32 has become the main mid-GWP choice for split air conditioners, and our R32 supplier spec sheet and packaging guide explains its formats.

RefrigerantTypeApprox. GWPSafety classTypical use
R290Natural hydrocarbon~3A3Small commercial refrigeration, small ACs, heat pumps, chillers
R22HCFC~1,810A1Servicing legacy systems
R32HFC~675A2LSplit ACs, heat pumps
R410AHFC blend~2,088A1Existing AC and heat pump fleet

GWP values vary slightly depending on the IPCC assessment report used. Choose by regulation, equipment design and technician capability, not by GWP alone.

Typical R290 Applications

Commercial and plug-in refrigeration

The largest R290 use is in self-contained commercial refrigeration: display coolers, ice-cream freezers, bottle coolers, vending machines, beverage dispensers and small cold-room condensing units. Sealed plug-in units keep the charge small and fixed at the factory, which fits charge limits well. R290 can also serve in low-temperature applications because its boiling point is about -42 °C (-44 °F).

Air conditioning and heat pumps

R290 is increasingly used in split and monobloc air conditioners and in air-to-water heat pumps. Monobloc heat pumps keep the propane entirely inside an outdoor unit, with water circulating indoors. This is a major reason R290 is growing in European residential heating. Efficiency can be strong, particularly in higher-temperature heating duty, because of the favourable critical temperature.

Other uses

R290 is also used in small chillers, dehumidifiers, some automotive-adjacent and industrial process cooling, and in blends with R600a or R1270 for specific designs. It is not a general replacement for HFC refrigerants in fleets of existing equipment, and it is less used where large charges would exceed safety limits.

Sourcing R290 Refrigerant for Wholesale and Export

Purity and what to ask for

Refrigerant-grade propane is typically specified at high purity, often 99.5 % or better, with tightly limited moisture and low levels of other hydrocarbons such as propylene. Impurities can affect compressor life and capacity. Ask for a specification and a certificate of analysis that matches the batch, and confirm that the product is refrigerant grade, not LPG.

Packaging and documentation

Buyers commonly choose between disposable cylinders and refillable cylinders, depending on market regulation and logistics. Flammable cargo needs correct dangerous-goods paperwork, labelling and a carrier that accepts Class 2.1 gas. Cylinder approvals vary by destination, so verify what your market accepts. Our guide to buying refrigerant gas in bulk explains packaging choices and shipping considerations in detail.

Making an enquiry

Refrigerant Gas International LTD is a manufacturer of refrigerant gas and steel cylinders, founded in 2004, with production in Zhejiang, China and Gebze/Kocaeli, Turkey. We supply R290 propane and R600a isobutane in cylinders, alongside HFC and HCFC refrigerants, helium and manifold gauges, and we support OEM brand supply. Our pressure vessel production holds an AQSIQ licence, with DOT, KGS and CE certificates. We work through enquiries and quote requests: send your destination, required packaging and volume, and our team will respond with the relevant details.

Conclusion

R290 refrigerant is propane used as a low-GWP, high-efficiency working fluid. Its properties suit small sealed systems, but its A3 flammability means charge limits, ventilation, ignition control and trained technicians are essential. It is not a retrofit option for R22, R410A or R32 equipment. Buyers should confirm purity, cylinder type, documentation and the standards that apply in their destination market before ordering.

Frequently asked questions

Is R290 refrigerant flammable?

Yes. R290 is propane and is classified A3, the highest flammability class in ISO 817 and ASHRAE 34. It burns when mixed with air at roughly 2.1 % to 9.5 % by volume and ignited, so ignition sources must be controlled.

What is R290 refrigerant made of?

R290 is pure propane (C3H8), a natural hydrocarbon. Refrigerant grade is purified and dried, unlike LPG, which contains odorant and other components unsuitable for sealed refrigeration circuits.

Can I replace R22 with R290 in an existing system?

No. R290 is not a drop-in replacement. Systems designed for R22 are not built for flammable refrigerants, and retrofitting them with propane is prohibited or discouraged under most standards and regulations. R290 should only be used in equipment designed and approved for it.

What is the GWP of R290?

R290 has a GWP of about 3 over 100 years, with zero ozone depletion potential. The exact figure varies slightly by IPCC assessment report, but it is far lower than R22, R410A or R32.

Is R290 more efficient than R32 or R410A?

It can be, in equipment designed for it. R290 has high latent heat and good heat-transfer behaviour, which often helps efficiency. Actual performance depends on the system design, heat exchangers and operating conditions.

Do I need special training to work with R290?

Yes, in most markets. Technicians should be trained in flammable refrigerant handling, use hydrocarbon-rated recovery equipment and leak detectors, and follow manufacturer instructions. Certification requirements differ between countries.

How is R290 supplied and transported?

It is supplied in steel cylinders, either disposable or refillable, and transported as a flammable gas under dangerous-goods rules such as ADR, IMDG, IATA or DOT. Valve connections and cylinder approvals differ by region, so confirm them with your supplier.

Is R290 the same as LPG or cooking propane?

No. LPG usually contains odorant, other hydrocarbons and higher moisture. Using it in a refrigeration system can damage components. Always use refrigerant-grade R290 with a specification suitable for the equipment.