Choosing an R32 refrigerant gas supplier takes more than comparing the label on a cylinder. R32 (difluoromethane, HFC-32) is a single-component, mildly flammable refrigerant that now sits inside millions of split air conditioners and heat pumps. Importers must get purity, packaging, valves and transport paperwork right before a container leaves the factory. This guide is a practical specification and packaging reference for wholesale buyers, distributors and HVAC businesses worldwide. It explains the key physical and purity data, how 10 kg and 20 lb cylinders differ from other formats, when an ISO tank makes sense and what to put in an enquiry. Refrigerant Gas International LTD, a refrigerant and steel cylinder manufacturer founded in 2004, supplies R32 factory-direct to export markets.
In this article
- Key takeaways
- R32 refrigerant gas specification sheet: what the numbers mean
- Where R32 is used and what to check before you stock it
- R32 cylinder 10 kg, 20 lb and other fill sizes
- ISO tanks and bulk R32 refrigerant wholesale
- Certificates and documents to expect from an R32 refrigerant gas supplier
- How to evaluate an R32 refrigerant gas supplier
- How to request a quote to buy R32 gas
- Conclusion
Key takeaways
- R32 is a pure, single-component HFC with zero ozone depletion potential, a GWP of roughly 675 (IPCC AR4 basis) and an ASHRAE safety class of A2L (lower toxicity, mildly flammable).
- Ask which purity standard applies. AHRI 700 is the common reference, with 99.5% minimum purity by weight and tight limits on moisture, acidity and non-condensable gases.
- A 10 kg cylinder holds about 10% more gas than a 20 lb (9.07 kg) cylinder, so compare cost per kilogram, not per cylinder.
- Valve outlets, cylinder approvals and labels differ between regions. State your destination country in the first enquiry.
- R32 is transported as UN 3252, Class 2.1 flammable gas, so shipping rules are stricter than for non-flammable refrigerants such as R134a.
R32 refrigerant gas specification sheet: what the numbers mean
A specification sheet is only useful if you know which lines matter commercially. For R32, a handful of values decide whether the product will perform in equipment and whether it can be shipped legally.
Identity and physical properties
R32 has a low boiling point and a high operating pressure, which is why equipment and cylinders must be designed for it. The table below summarises typical reference values from published refrigerant data. Always confirm the exact figures on the supplier's own sheet.
| Property | Typical value |
|---|---|
| Chemical name / formula | Difluoromethane (HFC-32), CH2F2 |
| CAS number | 75-10-5 |
| Molar mass | 52.02 g/mol |
| Boiling point at 1 atm | -51.7 °C (-61.1 °F) |
| Critical temperature | 78.1 °C (172.6 °F) |
| Critical pressure | About 5.8 MPa (58 bar, 838 psi) |
| Vapour pressure at 25 °C (77 °F) | About 17 bar absolute (roughly 245 psi) |
| Ozone depletion potential (ODP) | 0 |
| GWP, 100-year | About 675 (AR4); later IPCC reports give somewhat higher values |
| ASHRAE 34 safety class | A2L |
| UN number / transport class | UN 3252, Class 2.1 (flammable gas) |
Purity and impurity limits
R32 refrigerant purity is the line buyers ask about most, but purity alone is not enough. Moisture, acidity and non-condensable gases (mainly air) damage compressors and clog expansion devices. The AHRI 700 specification is widely used as a benchmark, with a minimum purity of 99.5% by weight, moisture of 10 ppm by weight or less, acidity of 1 ppm by weight or less and non-condensables in the vapour phase of 1.5% by volume or less. Some markets reference other standards, so write down the standard you need and ask the supplier to confirm it in writing for the grade you are buying.
Safety and environmental data
R32 burns only within a narrow range and with high ignition energy, which is why it is classed A2L rather than A3 like propane. Its lower flammability limit is about 14.4% by volume in air. That classification drives handling, ventilation and charge-limit rules in technician training and equipment standards. Its GWP is about one third of R410A, which is a main reason it is replacing R410A in new residential and light commercial equipment.
Where R32 is used and what to check before you stock it
Demand for R32 comes mainly from new equipment and its servicing. Knowing the application helps you pick pack sizes and forecast volumes.
Equipment that uses R32
The largest use is in single-split and multi-split air conditioners, followed by air-to-water heat pumps, small chillers and some packaged units. R32 also appears as a component in blends such as R410A (50% R32 and 50% R125) and R407C. Your market mix decides how much stock you need. In regions where R410A equipment is still dominant, R32 sales grow slowly with each new product generation. A side-by-side view is in our R32 vs R410A comparison for distributors and importers.
Charge size, oil and compatibility
- No mixing: never top up an R410A system with R32 or the reverse. They are different refrigerants with different pressures and glide behaviour.
- Charge mass: R32 systems generally need less refrigerant by mass than comparable R410A systems. Follow the nameplate charge on each unit.
- Lubricant: R32 equipment normally uses POE (polyolester) oil. Technicians should follow the manufacturer's service instructions.
- Retrofit: do not convert existing R410A equipment to R32 unless the equipment manufacturer approves it.
Regional rules and phase-down policy
HFC phase-down schedules under the Kigali Amendment differ by country group, and some regions add their own quotas, licensing or reporting rules. Flammable-refrigerant installation rules also vary. R32 is often an easier compliance choice than R410A, but you must check import permits, quota systems and technician certification requirements in your own country before you place an order.
R32 cylinder 10 kg, 20 lb and other fill sizes
Packaging is where an R32 refrigerant wholesale purchase becomes practical. Fill size sets your handling cost, your storage space and how easily your customers can use the product.
Disposable versus refillable cylinders
Disposable (one-way) cylinders are lighter, need no return logistics and suit distributors who sell to contractors in many small lots. Refillable steel cylinders are heavier and more robust, and suit bulk users and regional operators who can manage returns. Refrigerant Gas International manufactures its own steel cylinders and ships both disposable and refillable formats, so the cylinder and the gas can come from one factory.
Common fill sizes compared
The sizes below are nominal sizes common in the market. They are not a list of what any one factory fills. Confirm available sizes for your destination in your enquiry.
| Nominal fill | Metric | Imperial | Typical buyer |
|---|---|---|---|
| 20 lb | 9.07 kg | 20 lb | Contractors in markets that buy by the pound |
| 10 kg | 10 kg | 22.0 lb | Distributors and service companies in metric markets |
| 25 lb | 11.3 kg | 25 lb | Mixed-use wholesalers |
| 30 lb | 13.6 kg | 30 lb | Larger service fleets |
| 50 lb | 22.7 kg | 50 lb | Commercial installers, bulk resellers |
Because a 10 kg cylinder contains about 0.9 kg more gas than a 20 lb cylinder, a quote per cylinder can mislead. Convert every offer to a price per kilogram of net refrigerant before comparing.
Valves, fittings and labelling
Valve outlet types are not the same everywhere, and flammable-class refrigerants may require different connections from non-flammable ones. Labels must also show the UN number, the flammable gas hazard marking and the net weight, in the language and format your country requires. Tell your supplier the destination and any labelling requirements before production, not after.
ISO tanks and bulk R32 refrigerant wholesale
When you move R32 in volume, individual cylinders become expensive to handle. Bulk formats cut handling and can lower cost per kilogram at the destination.
When an ISO tank makes sense
An ISO tank suits importers who have a filling plant, a distribution business that repacks into cylinders, or large industrial users with transfer facilities. It needs a receiving site with the right connections, trained staff and local permits for flammable gas. For buyers without those, cylinders remain the safer and simpler route. Our guide to buying refrigerant gas in bulk, including packaging and worldwide shipping goes deeper on the trade-offs.
Filling limits and transport classification
Liquefied gases are filled to a maximum ratio of mass to water capacity, set by transport regulations, so that the container never becomes completely full of liquid as temperatures rise. This applies to cylinders and tanks alike. R32 ships as UN 3252, Class 2.1, and rules for sea, road and air differ. Cylinders of flammable gas are normally forbidden on passenger aircraft, and carriers may impose their own restrictions. Ask your freight forwarder to check each leg of the route, and compare how many cylinders fit in a 20 ft or 40 ft container so you can calculate true landed cost per kilogram.
Certificates and documents to expect from an R32 refrigerant gas supplier
Paperwork protects you at customs and in the event of an incident. A serious supplier should be able to show you the approvals behind both the gas and the container.
Pressure vessel approvals
Cylinders are pressure vessels, so approvals matter as much as gas quality. Refrigerant Gas International holds a pressure vessel production licence from AQSIQ, together with DOT, KGS and CE certificates. These relate to cylinders for China, the United States, Korea and Europe respectively. Check that the approval you need for your market matches the cylinder type you order. A cylinder approved for one region is not automatically accepted in another.
Shipping and product documents
Typical export documents include the commercial invoice, packing list, bill of lading or air waybill, a safety data sheet (SDS) and dangerous goods paperwork for UN 3252. Your importing country may also require import permits, HFC quota evidence or product registration. Ask early which documents the supplier can provide, and verify the list against your customs broker's requirements. For a broader due-diligence list, see the refrigerant gas manufacturer checklist for importers.
How to evaluate an R32 refrigerant gas supplier
Many pages list R32 as a product. Few help you judge the source. Use the points below to separate manufacturers from intermediaries and to avoid costly surprises.
Factory-direct or trader
A factory-direct supplier controls production, cylinder filling and quality checks in one chain, which makes questions about batch, purity and cylinder origin easier to answer. A trader may buy from several factories, so the product you receive can change between shipments. Refrigerant Gas International produces in Zhejiang, China, and Gebze/Kocaeli, Turkey, and exports to Europe, the USA, Asia, the Middle East, Africa, Japan and Korea.
Questions that separate suppliers
- Which purity standard does your R32 meet, and can you confirm it in writing?
- Who makes the cylinders, and which approvals do they carry?
- Which valve type and label format will be used for my destination?
- Can the supplier provide the SDS and dangerous goods documents for UN 3252?
- Which packaging options are available: disposable, refillable or ISO tank?
- Does the supplier offer OEM brand supply if I want my own brand?
Pricing for R32 moves with raw material and market conditions. Our article on what drives refrigerant gas cost explains the main factors using R410A as the example.
How to request a quote to buy R32 gas
Refrigerant Gas International sells through an enquiry and quote process, not an online checkout. A complete enquiry shortens the exchange and lets the sales team respond with accurate details on the first reply.
What to include in your enquiry
- Product: R32, and the purity standard you require.
- Packaging: disposable cylinder, refillable cylinder or ISO tank, plus the fill size you want (for example 10 kg or 20 lb).
- Quantity: expected volume per shipment and how often you buy.
- Destination: country and port, as valve, label and certificate needs depend on it.
- Branding: whether you need your own label or OEM brand supply.
- Other products: R410A, R134a, R404A, R407C or other refrigerants you might ship in the same container.
OEM brand supply and private labelling
If you distribute under your own name, OEM brand supply allows R32 to be supplied under your brand. Send your label requirements early, because legal markings such as hazard symbols and net weight must stay compliant in your market. If you also stock R410A, compare the two with the R410A vs R32 stocking guide for distributors.
Conclusion
A good R32 refrigerant gas supplier gives you a clear specification, a defined purity standard, cylinders with the right approvals and the documents your customs authority will ask for. Compare fill sizes by net kilograms, confirm valves and labels for your destination and match the packaging format to your handling capacity. Send a complete enquiry covering product, packaging, quantity, destination and branding, so the supplier can respond with details that fit your market.
Frequently asked questions
What is R32 refrigerant and what is it used for?
R32 is difluoromethane (HFC-32), a single-component refrigerant used mainly in split air conditioners, heat pumps and small chillers. It has zero ozone depletion potential and a lower GWP than R410A. It is classed A2L, meaning low toxicity and mild flammability.
What purity should R32 refrigerant have?
A common benchmark is AHRI 700, which sets minimum purity at 99.5% by weight, with low limits for moisture, acidity and non-condensable gases. Other standards exist in some markets. Name the standard you need in your enquiry and ask the supplier to confirm it in writing.
How much gas is in an R32 10 kg cylinder compared with a 20 lb cylinder?
A 10 kg cylinder holds 10 kg (22.0 lb) of refrigerant, while a 20 lb cylinder holds about 9.07 kg. The 10 kg cylinder therefore has roughly 10% more gas. Always compare offers by price per kilogram of net refrigerant.
Is R32 dangerous to ship?
R32 is shipped as UN 3252, Class 2.1 flammable gas, so it needs dangerous goods labelling, documents and a carrier that accepts it. Rules differ for sea, road and air, and flammable gas cylinders are normally not allowed on passenger aircraft. Check each leg of the route with your freight forwarder.
Can I use R32 in an R410A air conditioner?
No, not unless the equipment manufacturer explicitly approves it. R32 and R410A have different pressures and properties, and R410A systems are not designed for a flammable A2L refrigerant. Follow the nameplate and service manual.
Should I choose disposable cylinders, refillable cylinders or an ISO tank?
Disposable cylinders suit distributors selling small lots with no return logistics. Refillable cylinders suit buyers who can manage returns, and ISO tanks suit importers with filling or transfer facilities and local permits for flammable gas. The right choice depends on volume and handling capacity.
How do I buy R32 gas from Refrigerant Gas International?
Purchases go through an enquiry and quote request, not an online checkout. Send the product, packaging, quantity, destination country and any OEM branding needs so the team can reply with details for your order.
Do R32 regulations differ between countries?
Yes. HFC phase-down timelines, quotas, import licensing, cylinder approvals and flammable refrigerant installation rules vary by country and region. Check your local requirements before ordering.