Anyone searching for an R22 freon gas 13.6kg price is usually trying to answer a bigger question: which supplier can ship a compliant, correctly specified product to my market, in the format my customers use? R22 (HCFC-22) is now a regulated, shrinking product, so the cylinder size, purity, certificates and paperwork matter as much as the number on the quote. This guide is written for importers, wholesalers, distributors and HVAC and refrigeration businesses. It explains the formats available, how purity is judged, which cylinder approvals matter, how an export shipment is organised, and what to check with your own authorities first. It is general guidance, and rules differ by country.

Key takeaways

  • A 13.6kg (30 lb) cylinder is the standard small-format pack for R22 service markets, with 22.7kg (50 lb), larger refillable cylinders and ISO tanks used for volume supply.
  • The final price depends on raw material and quota conditions, packaging type, freight and order size, so quotes are issued per enquiry rather than fixed on a page.
  • Ask for a clear purity specification, moisture and acidity limits, and confirmation of whether the gas is virgin or reclaimed.
  • Cylinder approvals such as DOT, KGS and CE, and a pressure vessel production licence, should match the destination market.
  • R22 import is restricted or banned in some countries, so confirm licensing and quota rules before you commit to an order.
  • Many buyers now pair R22 with replacement refrigerants such as R407C, R410A, R32, R438A and R422D.

What R22 freon gas is and where the market stands in 2026

R22 is chlorodifluoromethane, an HCFC refrigerant that was the dominant choice for air conditioning and medium-temperature refrigeration for decades. Many systems built before the early 2000s still run on it, which is why service demand continues even though new equipment has largely moved to other gases.

Basic properties buyers should know

  • Chemical name and formula: chlorodifluoromethane, CHClF2.
  • Boiling point: about -40.8°C (-41.4°F) at atmospheric pressure.
  • Safety class: non-flammable and low toxicity under common refrigerant classification (A1).
  • Transport: shipped as a liquefied compressed gas, commonly under UN 1018, class 2.2.
  • Environmental values: ozone depletion potential of roughly 0.05 and a global warming potential commonly cited around 1,760 to 1,810 depending on the assessment report used.

Phase-out status differs by region

R22 is controlled under the Montreal Protocol. Developed countries have already reduced consumption to a very small servicing allowance, and several jurisdictions prohibit the import or use of virgin R22 altogether. Developing countries (Article 5 parties) follow a longer schedule that ends general consumption around 2030, with a limited servicing tail permitted afterwards until 2040. Because each country implements this differently through quotas, licences and bans, the same cylinder can be a routine import in one market and prohibited in another. Our overview of the refrigerant phase-out schedule gives wider context on where the industry is heading.

R22 freon gas 13.6kg price: what actually shapes a quote

Buyers often want a single figure for a 13.6kg cylinder. In practice, no honest supplier can give one that holds across every destination, because the cost is built from several moving parts. Refrigerant Gas International works on an enquiry and quote request basis, so the figure you receive reflects your specification, packaging and delivery route, not a generic list.

Raw materials and production controls

R22 is made from fluorspar-derived hydrofluoric acid and chloroform. Movements in those inputs, together with production quotas for HCFCs in the producing country, feed into the cost of the finished gas. Because quotas are tightening over time, R22 does not behave like a freely scaled commodity. For a sense of how input costs have moved the broader refrigerant market, see our note on what really drives refrigerant gas cost, which applies the same logic to R410A.

Cylinder type and packaging

The container is a real cost line. A disposable cylinder, a refillable cylinder and an ISO tank each carry a different cost per kilogram of gas, and each has different handling at the destination. Pack-out details such as cartons, pallets, valve type and private labelling also change the quote.

Freight, destination and order size

Sea freight rates, port charges, insurance and inland delivery vary widely by route. Order volume affects how efficiently a container is filled. When you compare two offers, check that both use the same trade terms (for example FOB or CIF) and the same packaging, otherwise the difference may simply be what is included.

R22 cylinder formats: 13.6kg, 22.7kg, refillable and ISO tank

Choosing the right format is one of the most practical decisions in R22 sourcing. It affects how easily technicians can handle the product, how the cargo is loaded and whether your local rules allow the container type at all.

Disposable cylinders for service markets

The 13.6kg (30 lb) cylinder is the format most technicians recognise, and the 22.7kg (50 lb) cylinder is common for workshops and larger service contractors. They are one-way packs, easy to distribute through counter sales. Some countries restrict disposable refrigerant cylinders or require specific marking, so verify before ordering.

Refillable cylinders for repeat supply

Refillable cylinders suit distributors with a return loop and a filling or reclamation capability. They are built to a pressure vessel standard and need periodic inspection and test marking. They only make sense when you can manage cylinder circulation across borders.

ISO tanks for bulk shipments

ISO tanks move large quantities of liquid refrigerant in a single transport unit, usually to buyers who repackage into smaller cylinders locally. They require suitable filling and discharge facilities at the destination.

FormatApprox. gas weightTypical useMain consideration
Disposable cylinder13.6kg (30 lb)Service and retail distributionCheck local rules on one-way cylinders
Disposable cylinder22.7kg (50 lb)Workshops and contractorsHeavier handling, fewer cylinders per kg
Refillable cylinderLarger fill sizesDistributors with a return loopInspection, test dates and return logistics
ISO tankBulk tonnageRepackagers and large importersDischarge and transfer equipment needed

Confirm the exact sizes and fill weights available for your order through an enquiry. Our guide to buying refrigerant gas in bulk covers packaging and shipping choices across all refrigerants.

R22 purity and specification: what to ask before you order

Two R22 offers can look identical on paper and perform very differently in a compressor. A written specification is the way to compare them fairly.

Purity and impurity limits

Industry practice for new refrigerant commonly references AHRI 700 style limits, which for R22 call for a high purity level of 99.5% or better, with defined limits on other organic impurities. Ask which standard the supplier tests against and the figure it reports for your batch. A bare claim of high purity without a reference method is not enough.

Moisture, acidity and non-condensables

Moisture and acid are what damage systems. Request the stated limits for water content, acidity and non-condensable gases, plus any residue figure. Excess moisture can freeze at expansion devices and create acids with the lubricant, while air in the cylinder raises head pressure.

Virgin versus reclaimed R22

Some markets now rely on reclaimed R22 because virgin supply is restricted. State clearly in your enquiry which one you need, because legal treatment and labelling often differ. A supplier should be able to say plainly what its product is and how it is documented.

  • Ask for the test standard and the reported purity.
  • Request water, acidity and non-condensable limits.
  • Confirm virgin or reclaimed status in writing.
  • Ask what batch or lot identification appears on the cylinder.

Our manufacturer checklist for importers lists more questions worth putting to any factory.

Certification and cylinder compliance for R22 exports

With a pressurised gas, the cylinder is as regulated as the contents. Customs, port authorities and your own inspectors will look at cylinder approvals before they look at the gas.

Pressure vessel approvals

Refrigerant Gas International holds a pressure vessel production licence from AQSIQ, and its cylinders carry DOT, KGS and CE certificates. Those relate to markets including the United States, Korea and the European Union. When you evaluate any supplier, ask who makes the cylinders, which licence covers them and whether the certificate matches the cylinder model you will receive.

Matching certificates to the destination

A certificate that satisfies one market may not satisfy another. Cylinders for the EU follow European transportable pressure equipment rules, while US shipments refer to DOT specifications. Many other countries accept one of these or have their own scheme. Check with your local competent authority which marking you need and whether cylinders must be tested within a set period before import.

Documents that travel with the cargo

A typical set includes a commercial invoice, packing list, bill of lading or airway bill, a safety data sheet and any certificates your authority requests. If you need a certificate of analysis or other specific papers, say so at enquiry stage so it can be discussed before the order is confirmed. Do not assume a document is included unless it is stated.

How the R22 export process works, step by step

Exporting a regulated refrigerant is mostly about sequence. Doing the checks in the right order avoids stranded containers.

From enquiry to confirmed specification

  1. Confirm legality first. Check that your country allows the import and that you hold any needed licence or quota.
  2. Send a detailed enquiry. Include cylinder size, quantity, destination port, trade terms, labelling needs and whether OEM branding is required.
  3. Review the quote and specification. Compare purity, packaging and included documents, not only the figure.
  4. Confirm packaging and marking. Agree cylinder type, cartons or pallets and label content.
  5. Arrange shipment. Production is in Zhejiang, China and Gebze/Kocaeli, Turkey, so route and origin can be discussed according to your destination.

Dangerous goods shipping basics

R22 is a class 2.2 non-flammable gas, but it still needs dangerous goods declarations, correct UN marking and a carrier that accepts pressurised gas. Not every shipping line or route does. Use a freight forwarder with experience in compressed gases.

Receiving and inspecting the shipment

On arrival, check cylinder marking against the paperwork, look for valve damage or leakage, and record batch numbers. Report any problem promptly with photos so it can be traced through the documents.

Check import rules before you buy R22 wholesale

This is the section many sourcing pages skip. Because R22 is an ozone-depleting substance, legal access depends on where you are.

Licences and quotas

Most countries that still allow R22 import operate an ozone-depleting substance licensing system, often with annual quotas allocated to registered importers. You normally need a licence before the cargo is shipped, not after it arrives. Your national ozone unit or customs authority can tell you how to apply.

Customs classification

Chlorodifluoromethane is normally classified under Harmonized System subheading 2903.71, though national tariff lines can extend this. Using the right code and describing the product correctly on the invoice reduces clearance delays.

Region-by-region differences

  • European Union: virgin R22 use for servicing has been banned for years, with narrow rules for reclaimed material.
  • United States: production and import of new R22 ended from 2020, so supply is limited to existing stocks and reclaimed gas.
  • Many Article 5 countries: imports remain possible within quotas, with reductions continuing toward 2030.
  • Others: some countries have earlier bans on R22 equipment imports or stricter labelling.

These are summaries, not legal advice. Always confirm the current position with your local authority before ordering.

R22 replacement refrigerants to offer alongside

A distributor who only carries R22 is exposed to quota cuts. A balanced range protects your customers and your business, and Refrigerant Gas International supplies several of the likely alternatives.

Drop-in style retrofit blends

R438A and R422D are retrofit blends intended for existing R22 systems, usually with limited changes. Compatibility with the installed oil, capacity and discharge temperature should be checked with the equipment maker or a qualified technician before any conversion.

Long-term replacements for new equipment

R407C and R410A were the main replacements in air conditioning, and R32 is now widely used in new split systems. Hydrocarbons such as R290 are used in suitable, purpose-built equipment. Our comparisons of R32 and R410A for distributors and our guide to R404A and R507 for commercial refrigeration help you decide what to stock.

RefrigerantTypical role relative to R22Key note
R438ARetrofit blendCheck oil and system compatibility
R422DRetrofit blendOften used in medium-temperature systems
R407CReplacement in air conditioningZeotropic blend with temperature glide
R410AReplacement in new air conditioningHigher operating pressure, needs matched equipment
R32Newer air conditioning designsMildly flammable, lower GWP than R410A

Conclusion

The R22 freon gas 13.6kg price you receive depends on raw material conditions, packaging, freight and order size, so the sensible route is an enquiry with a clear specification. Focus on the format that suits your market, a written purity and moisture specification, cylinder certification that matches your destination, and the correct export documents. Confirm your own import licence and quota position first, because rules differ widely between countries. Refrigerant Gas International supplies R22 and related refrigerants factory direct, with OEM brand support and packaging in canisters, cylinders and ISO tanks, through an enquiry and quote process.

Frequently asked questions

What is the standard R22 cylinder size?

The most common small format is the 13.6kg (30 lb) disposable cylinder, followed by the 22.7kg (50 lb) cylinder. Larger refillable cylinders and ISO tanks are used for volume supply. Confirm exact sizes and fill weights through an enquiry.

Why is there no fixed R22 freon gas 13.6kg price?

The cost depends on raw material and quota conditions, the type of cylinder, freight route, trade terms and order size. Because those vary by buyer, quotes are issued per enquiry. Compare offers using the same packaging and terms.

Is R22 still legal to buy and import?

It depends on the country. Some regions ban virgin R22 or restrict it to reclaimed gas, while many developing countries still allow imports within licences and quotas. Check with your national ozone unit or customs authority before ordering.

What purity should I expect from R22?

New R22 is commonly specified against AHRI 700 style limits, with high purity and defined limits for moisture, acidity and non-condensables. Ask the supplier which test standard it uses and what figures apply to your batch.

Which certificates matter for R22 cylinders?

Cylinder approvals that match the destination market, such as DOT for the United States, KGS for Korea and CE for Europe, plus a pressure vessel production licence. Refrigerant Gas International holds an AQSIQ pressure vessel licence and DOT, KGS and CE certificates.

What documents are needed to export R22?

Usually a commercial invoice, packing list, transport document, safety data sheet, dangerous goods declaration and any import licence or certificate your authority requires. State any special document needs at enquiry stage.

Can I get R22 under my own brand?

Refrigerant Gas International offers OEM brand support, so private labelling can be discussed in your enquiry. Whether R22 itself can be imported under your brand depends on your local regulations.

What can I sell instead of R22?

Common options are the retrofit blends R438A and R422D, and R407C, R410A or R32 for newer equipment. Hydrocarbons like R290 suit purpose-built systems. Always check compatibility with the equipment maker.