An R290 propane refrigerant cylinder looks like a simple product, but it is a pressurised, flammable-gas package that must be sized, certified, labelled and documented correctly before it can cross a border. For importers, distributors and HVAC wholesalers, the cylinder choice affects freight cost, handling safety, local compliance and how easily technicians can use the gas on site. This guide explains typical R290 cylinder sizes, the difference between disposable and refillable packs, how UN1978 dangerous-goods rules apply by sea, road and air, and which documents to prepare for export. Rules differ from country to country, so treat this as a planning framework and confirm the details with your freight forwarder and local authority.
In this article
- Key takeaways
- What is inside an R290 propane refrigerant cylinder
- R290 cylinder sizes: from 5 kg packs to ISO tanks
- Disposable or refillable R290 cylinders: which suits your market
- How R290 is classified for dangerous-goods shipping
- Documents for R290 export and import
- Choosing an R290 bulk supplier: what to ask
- Safe storage, handling and charge limits for R290 buyers
- Common R290 shipping and packaging mistakes
- Conclusion
Key takeaways
- R290 is pure propane: UN1978, Class 2.1 flammable gas. Every shipment must follow dangerous-goods rules for the transport mode used.
- Common market formats run from small cans through 5 to 6 kg service cylinders (including the 12 lb size) up to larger refillable cylinders and ISO tanks. Exact availability should be confirmed by enquiry.
- Cylinder fill is limited by water capacity and test pressure, so a nominal size such as 5 kg only works if the cylinder volume supports it.
- Valve thread, cylinder approval marks and labelling language vary by region and can block import if they do not match.
- A clean document set (commercial invoice, packing list, SDS, dangerous-goods declaration, transport document and cylinder certificates) prevents most delays.
- Air freight of R290 is heavily restricted; most export volume moves by sea or road.
What is inside an R290 propane refrigerant cylinder
R290 is the refrigerant designation for propane (C3H8). It is a hydrocarbon natural refrigerant with a very low global warming potential (about 3 on a 100-year basis) and zero ozone depletion potential, which is why it is widely used in new domestic and light commercial refrigeration and in a growing number of split and monobloc air conditioners. For a deeper look at its behaviour in equipment, see our guide to R290 properties, safety rules and applications.
Grade and purity to specify
Refrigeration-grade R290 is not the same as fuel propane. Refrigeration systems are sensitive to moisture, unsaturated hydrocarbons and other contaminants, and compressor oil reacts badly to impurities. When you request a quote, state that you need refrigeration-grade propane, name the purity level your equipment manufacturers require, and ask for a certificate of analysis or equivalent specification with the shipment. Do not assume a purity figure; confirm it in writing with the supplier.
Properties that drive packaging decisions
Several physical properties explain why R290 packaging is regulated the way it is:
- Boiling point: about -42 °C (-44 °F), so it is stored as a liquefied gas under its own vapour pressure.
- Flammability: classified A3 (higher flammability, lower toxicity) under ISO 817 and ASHRAE 34. The lower flammable limit is roughly 2.1% by volume in air.
- Vapour pressure: rises quickly with temperature, so cylinders must never be overfilled or left in direct sun or hot containers.
- Heavier than air: leaked gas collects low, in pits and drains, which affects warehouse design.
R290 cylinder sizes: from 5 kg packs to ISO tanks
There is no single global standard R290 cylinder. Sizes follow local habits: kilograms in most of the world, pounds in North America and some other markets. The table below summarises formats you will commonly see in the market. It is indicative only; check the specific sizes, valves and approvals available for your destination through a quote request.
| Format | Typical net fill | Typical use | Buyer notes |
|---|---|---|---|
| Small can or mini cylinder | About 300 to 500 g | Domestic fridge service, small repairs | Often consumer or workshop retail; check local rules on pressurised retail packs |
| Service cylinder | About 5 to 6 kg (roughly 11 to 13 lb) | Field technicians, small contractors | Includes the popular 5 kg and 12 lb sizes |
| Mid-size cylinder | About 9 to 15 kg | Workshops, equipment manufacturers | Heavier to handle; check trolley and storage limits |
| Large refillable cylinder | Tens of kilograms | Factory filling lines, distributors | Needs return logistics and a refill programme |
| ISO tank | Multiple tonnes | Bulk supply to fillers and OEM plants | Needs receiving equipment and trained staff |
R290 gas 5kg and the 12 lb cylinder
The two sizes buyers search for most are the R290 gas 5kg pack and the R290 12 lb cylinder. They are close but not identical: 5 kg equals about 11 lb, while 12 lb equals about 5.4 kg. If your customers use pounds, make sure your purchase specification states the net weight in both units and says whether the figure is net gas content or gross weight with the cylinder. A mismatch here is a common cause of disputes on arrival.
Larger refillable cylinders and ISO tanks
For volume buyers, bigger refillable cylinders and ISO tanks reduce packaging waste and cost per kilogram handled, but they require infrastructure on your side: a bonded or licensed storage area, transfer equipment, and staff trained in flammable-gas handling. If you plan to repack R290 into smaller cylinders, check whether local law allows it and what licences you need before ordering.
Fill limits and why they matter
Liquefied propane expands when it warms, so regulations cap how much can go into a cylinder, expressed as a filling ratio of kilograms per litre of water capacity. For propane this is roughly 0.4 kg per litre, with the exact figure depending on test pressure and the regulation applied. As a practical example, a cylinder rated for 5 kg of R290 needs a water capacity of around 12 litres or more. A cylinder with less capacity cannot legally hold a full 5 kg, so ask suppliers to state both the water capacity and the net fill.
Disposable or refillable R290 cylinders: which suits your market
Both cylinder types exist in the refrigerant trade, and the right choice depends on volume, local regulation and your returns infrastructure. Refrigerant Gas International supplies refillable and disposable refrigerant cylinders as well as ISO tanks, so the question is mostly about fit for your market.
Disposable cylinders
Disposable (non-refillable) cylinders are lighter, need no return logistics and suit markets with fragmented service networks. The downside is waste and, in some regions, regulation: certain jurisdictions restrict non-refillable containers for specific refrigerants. Check whether your country applies such rules to hydrocarbon refrigerants and how empty cylinders must be disposed of or recycled.
Refillable cylinders
Refillable cylinders are heavier and built to be tested and re-certified periodically. They suit distributors with regular volume, a return route and the ability to track cylinder serial numbers and inspection dates. They also lower long-term packaging waste. Remember that periodic requalification rules differ by country, and a cylinder that is in date in one market may need inspection before reuse in another.
Valves and connections
Flammable-gas cylinders commonly use left-hand threaded valves, but the exact outlet standard differs between Europe, North America, Asia and other regions. Technicians also use different hose and charging adapters. Before you order, confirm the valve type that your local technicians and regulators expect. Our R290 and R600a wholesale supply guide covers how natural refrigerant packaging is normally organised for distributors.
How R290 is classified for dangerous-goods shipping
Dangerous-goods classification is the same worldwide because it is based on the UN Model Regulations, but each transport mode applies it through its own code.
UN number, class and shipping name
Propane is UN1978, Class 2.1 (flammable gas), with the proper shipping name PROPANE. Many suppliers add the trade designation R290 in brackets on documents, but the UN number and the official name must always appear. Packing instructions for cylinders and the UN portable tank instruction for ISO tanks are set in the relevant codes.
Sea, road and air differences
- Sea: governed by the IMDG Code. This is the usual route for export cylinders and ISO tanks. Carriers and ports may impose their own booking, stowage and cut-off rules for Class 2.1 cargo.
- Road and rail: ADR and RID in Europe and neighbouring countries; other regions have their own national rules, often based on the UN model.
- Air: governed by the IATA Dangerous Goods Regulations and ICAO Technical Instructions. Flammable gas is highly restricted and is generally limited to cargo aircraft, with tight quantity limits. For most commercial volumes, plan on sea freight.
Marking and labelling
Each cylinder usually needs the UN number, the proper shipping name, the Class 2.1 flammable-gas hazard label, a gross and net weight, and the manufacturer or filler details. Outer packaging, pallets and the container itself also need placards or marks as required by the mode. Language requirements for labels differ by destination, so confirm whether bilingual labels are needed.
Documents for R290 export and import
Good paperwork is the difference between a smooth clearance and a container stuck at the port. Because R290 is dangerous goods, there are more documents than for non-flammable refrigerants such as R134a.
Documents prepared before shipment
Before the cargo is booked, make sure the following are ready:
- A proforma or confirmed order stating product, UN number, packaging type, net weight per unit and number of units.
- A safety data sheet (SDS) in the 16-section GHS format, in the language needed at the destination.
- Cylinder approval evidence, such as the production licence and approval marks relevant to the destination market.
- A certificate of analysis or product specification if your customer requires one.
Documents that travel with the cargo
- Commercial invoice and packing list, with cylinder serial numbers or lot numbers where required.
- Dangerous goods declaration signed by the shipper, in the form required by the transport mode.
- Bill of lading, sea waybill or air waybill showing the dangerous-goods details.
- Container packing certificate for sea shipments, confirming correct loading and securing.
- Certificate of origin where the buyer or customs requires it.
Destination-side paperwork
Import rules vary widely. Some countries require an import licence or permit for flammable refrigerants, registration under chemical regulations, a local safety representative, or approved warehouse storage. Others apply quotas or restrictions on specific refrigerants. Your customs broker should confirm these before the order is placed, not after the vessel sails. Our guide to buying refrigerant gas in bulk explains how packaging and worldwide shipping fit together.
Choosing an R290 bulk supplier: what to ask
An R290 bulk supplier should be able to answer technical and regulatory questions clearly, not only quote a price. Use the same discipline you would apply to any factory vetting exercise; our refrigerant gas manufacturer checklist gives a fuller framework.
Certifications and cylinder approvals
Because the cylinder is a pressure vessel, the maker's licences matter as much as the gas. Refrigerant Gas International is a refrigerant gas and steel cylinder manufacturer, with production in Zhejiang (China) and Gebze/Kocaeli (Turkey). It holds a pressure vessel production licence from AQSIQ, plus DOT, KGS and CE certificates. Always match the certificate to your destination: a DOT mark is relevant for the USA, KGS for Korea and CE-related conformity for Europe. Ask which approvals apply to the specific cylinder size you want.
OEM brand supply and labelling
If you sell under your own brand, ask about OEM brand refrigerant supply, including cylinder colour, label content and language. Confirm that your artwork keeps the mandatory hazard information visible and compliant for the destination.
What to include in your enquiry
Supply is handled through an enquiry and quote request process, so a complete enquiry speeds up the response. Include:
- Destination country and port, and whether you need sea or road delivery.
- Product (R290, or R290 together with R600a), purity requirement and application.
- Preferred packaging: disposable or refillable cylinders, or ISO tank, with target net weight or size.
- Valve type and labelling or OEM requirements.
- Estimated quantity per shipment and how often you plan to order.
Pricing, order quantities and delivery terms are confirmed in the quotation, not assumed in advance.
Safe storage, handling and charge limits for R290 buyers
Responsible supply does not end at the port. Distributors who store and resell R290 take on safety duties that depend on local law, so plan for them early.
Warehouse storage
- Store cylinders upright and secured, in a ventilated area away from ignition sources, heat and direct sun.
- Keep quantity within the limits set by your local fire and dangerous-goods rules.
- Separate R290 from oxidising gases and keep floor-level drains and pits clear of stored cylinders, since propane is heavier than air.
- Post no-smoking and flammable-gas signs, and keep suitable fire extinguishers and a written emergency plan.
Charge size limits in equipment
Product safety standards such as IEC 60335-2-40 and IEC 60335-2-89 limit how much flammable refrigerant can be placed in a refrigeration or air-conditioning circuit. Allowed charge depends on the edition of the standard, the room area and installation type, and local building codes can be stricter. This affects your customers directly: the cylinder size you sell should match the charge sizes technicians actually need, which is one reason 5 to 6 kg cylinders are so popular for service work.
Technician training
Working with R290 needs specific skills: leak detection with suitable equipment, spark-free tools, recovery rules, and ventilation. Many countries require certification for handling flammable refrigerants. Make sure your reseller network understands this before it starts stocking R290. Using a purpose-made refrigerant manifold gauge set that is rated for the refrigerant is part of safe practice.
Common R290 shipping and packaging mistakes
Most problems with R290 shipments are avoidable. These are the issues importers report most often across markets.
Documentation errors
- The UN number, proper shipping name or class is missing or inconsistent between the invoice, packing list and dangerous-goods declaration.
- The SDS is not in the destination language or is out of date.
- Net and gross weights are confused, or kilograms and pounds are mixed without conversion.
- The cylinder approval marks do not match what the destination authority accepts.
Packaging and loading errors
- Overfilled cylinders caused by assuming a nominal size can hold the full net fill.
- Poor securing or bracing in the container, which is a serious risk with flammable gas.
- Valve protection caps missing or damaged.
- Ordering the wrong valve thread for local charging equipment.
- Booking with a freight forwarder or carrier not approved to handle Class 2.1 cargo.
The simplest defence is a pre-shipment checklist shared between the supplier, forwarder and your customs broker, with one person responsible for confirming each item.
Conclusion
An R290 propane refrigerant cylinder is a regulated flammable-gas package, so size, fill limit, valve type, approvals and paperwork all matter as much as the gas itself. Choose a format that matches your market, from 5 kg and 12 lb service cylinders to refillable cylinders and ISO tanks. Prepare the UN1978 dangerous-goods documents early, and confirm destination rules with your forwarder and broker. When you are ready, send a complete enquiry to Refrigerant Gas International so the quotation reflects your packaging, labelling and destination needs.